Fisher & Paykel Refrigerator Fault 20 (Flapper Heater Under-Current)

Fault 20 concerns the flapper heater - a small element that keeps the damper flap between compartments from freezing into position. F&P's table logs this code when the current through that heater comes in low, pointing at an open-circuit heater…

What Fault 20 Means

Fault 20 concerns the flapper heater - a small element that keeps the damper flap between compartments from freezing into position. F&P's table logs this code when the current through that heater comes in low, pointing at an open-circuit heater or a broken connection to it.

Common Causes of Fault 20

  • The flapper heater element has gone open circuit
  • A Molex connection to the heater has worked loose
  • A broken lead in the run between module and damper

🔧 One Safe Check You Can Try

Nothing to test, but the sign worth reporting is a compartment that will no longer move off one temperature no matter how you set it, since a damper stuck open or shut behaves exactly that way.

⚠ Why You Shouldn't Go Further Than That

  • Unplug the refrigerator before the damper area is opened up, because this heater is fed from the same module that switches mains to the compressor.
  • The damper assembly is set up so the flap seats against its frame with very little clearance, and one disturbed and refitted by eye tends to leak cold air permanently.
  • A heater that measures open at the connector may still be fine at the element, with the break in the loom instead - only tracing it finds out.
  • Cold plastic in this part of the cabinet splits rather than bends, and the damper housing is not a part most owners can source separately.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Refrigerator Error Codes

Related Guides

Behavior Not Matching What's Described Above?

If Fault 20 is showing up earlier than expected, coming with other warning signs, or you're just not sure, book a trained technician for a proper diagnosis.

FAQ

Fault 20 FAQ

The damper it protects can freeze in one position, which leaves one compartment permanently over-cooled or permanently under-cooled regardless of the setting you choose.

No - the cabinet keeps running, which is why it can go unnoticed until someone looks at the problem log or wonders why one compartment ignores its setting.