Medium - Inspection Needed

Fisher & Paykel Refrigerator Fault 41 (Ice Maker Solenoid Transistor 2 Short)

Fault 41 reports the second of the two ice maker solenoid driver transistors as short circuit. The checks F&P lists are the same as for its partner code - measure the solenoid resistance, inspect the wiring and connections at both…

What Fault 41 Means

Fault 41 reports the second of the two ice maker solenoid driver transistors as short circuit. The checks F&P lists are the same as for its partner code - measure the solenoid resistance, inspect the wiring and connections at both the solenoid and the module, and change the power/control module if those prove sound.

Common Causes of Fault 41

  • A solenoid problem that has damaged the second driver transistor
  • A driver stage on the module failed short
  • Wiring damage shorting the solenoid circuit

🔧 One Safe Check You Can Try

Turn the refrigerator's water supply off at its valve as a precaution, then arrange the visit. There is no home test for a failed driver stage.

⚠ Why You Shouldn't Go Further Than That

  • Close the supply valve and unplug the refrigerator before any inspection, in that order, because the circuit involved switches mains to a water valve.
  • Two driver problems appearing together point at the solenoid rather than at coincidence, so the coil deserves measuring before a module is ordered.
  • Working on the fill line means moving the cabinet, and a water line kinked while it is pulled out becomes a new problem of its own.
  • Reusing an old compression olive when the joint goes back together is the usual way a repaired ice maker starts leaking a week later.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Refrigerator Error Codes

Related Guides

Still Seeing Fault 41?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

FAQ

Fault 41 FAQ

The module switches the circuit at more than one point, so F&P logs each driver separately. Seeing both codes together makes the solenoid itself the prime suspect.

Treat it as out of service and leave the water supply closed until it has been looked at.

Need a repair? We're ready to help. Call Now
Call Us Schedule