Medium - Inspection Needed

Fisher & Paykel Dishwasher FA2 Error (DW60 Series Frequency Check Failure)

FA2 sits beside FA0 in the same frequency consistency group. The manual attributes it either to a power frequency problem or to a controller malfunction, and names the harness connection as the thing to check before the controller is replaced.

What FA2 Means

FA2 sits beside FA0 in the same frequency consistency group. The manual attributes it either to a power frequency problem or to a controller malfunction, and names the harness connection as the thing to check before the controller is replaced.

Common Causes of FA2

  • An irregular incoming supply frequency
  • A harness connection degraded on the supply side of the controller
  • A controller whose measuring circuit has failed

🔧 One Safe Check You Can Try

Treat it as you would FA0: establish whether the machine is on a normal household circuit rather than a temporary, generator, or inverter supply, since that alone explains a fair share of frequency problems.

⚠ Why You Shouldn't Go Further Than That

  • The supply side of the controller must be dead before any connection there is disturbed, which means the breaker off rather than just the machine switched off.
  • FA0 and FA2 come from the same family of checks, so treating them as two unrelated problems leads to two repairs where one was needed.
  • A loose supply connection can arc quietly for a long time before anything else shows, and it is not something to re-make without the right terminals.
  • Fitting a board to cure what is actually a wiring or supply problem means the new board inherits the problem on day one.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Dishwasher Error Codes

Related Guides

Still Seeing FA2?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

FAQ

FA2 FAQ

They belong to the same check and neither is an emergency, but FA2 puts a harness connection explicitly on the list, so a loose terminal is worth ruling out early.

If it will run at all, it is not unsafe by itself - but a supply irregularity that affects one appliance is usually worth investigating for the rest of the circuit too.

Need a repair? We're ready to help. Call Now