Medium - Inspection Needed

Fisher & Paykel AquaSmart Washer Fault 41 (Thermistor Short Circuit)

Fault 41 is raised when the temperature sensor reports water above 230°F (110°C) - a reading no domestic washer will ever produce, since water boils well below it. F&P states the most likely explanation directly: a short circuit in the…

What 41 Means

Fault 41 is raised when the temperature sensor reports water above 230°F (110°C) - a reading no domestic washer will ever produce, since water boils well below it. F&P states the most likely explanation directly: a short circuit in the sensor line.

Common Causes of 41

  • A short circuit in the thermistor line
  • Moisture bridging the sensor connector pins
  • A thermistor that has failed to a short internally

🔧 One Safe Check You Can Try

There is nothing to measure at home. What helps is noting whether the machine has started refusing to heat, since a module told the water is already scalding will not call for any more heat at all.

⚠ Why You Shouldn't Go Further Than That

  • Unplug the machine before the sensor wiring is investigated, since a shorted low-voltage line can share a loom with mains wiring and the two are not obvious apart.
  • The documented reference is the same as for Fault 10, so measuring against the wrong figure or the wrong ambient gives a confident wrong answer either way.
  • Drying a damp connector is not a repair unless the route the water took has been found and closed.
  • A short that has already reached the module may have damaged its input, which is a second check the repair should include.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Washer Error Codes

Still Seeing 41?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

FAQ

41 FAQ

Very plausibly. A module reading 230°F believes the water is far hotter than any program needs, so it stops calling for heat entirely.

No - that is the point of the code. It is an impossible value, which is how the module knows it is looking at a short rather than at hot water.