Fisher & Paykel Dryer Fault 10 (24 Volt Supply Measurement Error)

Fault 10 is a 24 volt supply measurement error: the sensor module has measured low voltage on the actuator power supply. That rail is what drives the powered lid and door hardware, so a weak supply there shows up as…

What Fault 10 Means

Fault 10 is a 24 volt supply measurement error: the sensor module has measured low voltage on the actuator power supply. That rail is what drives the powered lid and door hardware, so a weak supply there shows up as actuator problems elsewhere. F&P names sensor module replacement as the remedy.

Common Causes of Fault 10

  • A failed low-voltage supply stage on the sensor module
  • An actuator loading the supply rail beyond its rating
  • A wiring problem dragging the actuator supply down

🔧 One Safe Check You Can Try

One breaker reset of two minutes is worth trying. If the dryer has also been throwing door or lid actuator codes, mention them together - they are very likely the same underlying supply problem.

⚠ Why You Shouldn't Go Further Than That

  • Switch off at the breaker before any module is reached, because the sensor module derives its low-voltage rail from the mains supply.
  • Replacing an actuator when the rail feeding it was low is a repair that cures nothing.
  • A rail dragged down by a failing actuator will do the same to a new module, so the load has to be checked too.
  • Fisher & Paykel has left the US laundry market, so a sensor module needs matching by exact reference rather than by appearance.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Dryer Error Codes

Still Seeing Fault 10?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

FAQ

Fault 10 FAQ

It would. The 24 volt rail is what powers the actuators, so a weak supply there produces door and lid problems that look mechanical but are not.

Report them together. A technician seeing Fault 10 alongside actuator codes will look at the supply first rather than replacing hardware.