Fisher & Paykel SmartDrive Washer Fault 132 (Single Current Trip)

Fault 132 covers SmartDrive phases 1 to 4 and records excess current detected momentarily in the motor or the electronic switches. F&P gives motor harness resistance figures that differ by phase - roughly 2.6 ohms on Phase 1, 12.2 ohms…

What 132 (SmartDrive) Means

Fault 132 covers SmartDrive phases 1 to 4 and records excess current detected momentarily in the motor or the electronic switches. F&P gives motor harness resistance figures that differ by phase - roughly 2.6 ohms on Phase 1, 12.2 ohms on Phases 2 to 4, and 32 ohms on Phases 5 and 6 - and asks specifically about water reaching the module.

Common Causes of 132 (SmartDrive)

  • Water leaking onto the motor control module
  • Corrosion or damage at the stator or rotor position sensor connections
  • A motor harness problem causing a momentary current spike

🔧 One Safe Check You Can Try

Unplug the machine and look underneath and behind it for any sign of water having run down onto the control area, because F&P asks that question directly as part of this diagnosis.

⚠ Why You Shouldn't Go Further Than That

  • Unplug the machine before anything near the stator is touched, because the current this code describes is the full motor drive current.
  • The correct resistance figure changes with the phase, and measuring against the wrong reference produces a confident wrong answer.
  • Water reaching the module is both the cause and a hazard, so the leak has to be found rather than dried up.
  • A brass bridge terminal damaged by water can look intact while no longer conducting properly, which needs inspection rather than a meter alone.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Washer Error Codes

Still Seeing 132 (SmartDrive)?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

FAQ

132 (SmartDrive) FAQ

The module watching the motor saw current spike beyond what the drive should ever produce and shut down to protect itself. Fault 132 records that it happened once, briefly.

F&P asks about it explicitly for this code, so yes - a leak reaching the control electronics is worth finding before anything is replaced.

Need a repair? We're ready to help. Call Now
Call Us Schedule