Fisher & Paykel Dryer

Fisher & Paykel DG62T27GW2

Model # DG62T27GW2 (product code 96150-A)

Fisher & Paykel dryer repair

The DG62T27GW2 is the final-form gas SmartLoad, and by this revision Fisher & Paykel had settled the platform: the burner assembly, the ignition sequence and the exhaust sensing are all shared with the electric machine except for the heat source itself. In practice a technician diagnosing one works the airflow path first and the burner second, because a restricted vent will make a perfectly healthy burner short-cycle on its thermostat and look failing.

Key Features

  • 27" SmartLoad gas dryer
  • Product code 96150-A on the rating plate
  • Electronic ignition and flame sensing
  • Lint bucket collection system

Most Common Issues on This Model

01

Gas valve coil failure

02

Igniter cracked or failing to reach temperature

03

Blocked vent run

04

Drum roller or belt wear

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

FAQ

Fisher & Paykel DG62T27GW2 FAQ

Often not. A vent that cannot carry the air away lets the cabinet overheat, and the thermostat then shuts the burner down repeatedly. Clearing the duct is the first step.

Yes. The appliance gas valve is shut off before any work near the burner or the valve, without exception.

Need a repair? We're ready to help. Call Now
Call Us Schedule