Medium - Inspection Needed

Fisher & Paykel Refrigerator Fault 23 (PC Sensor 2 Reading Hot)

Fault 23 is raised on the same second PC probe when its resistance falls under 660 ohms. F&P annotates that as the sensor reading hot, which in practice means the circuit has shorted somewhere and is presenting the control system…

What Fault 23 Means

Fault 23 is raised on the same second PC probe when its resistance falls under 660 ohms. F&P annotates that as the sensor reading hot, which in practice means the circuit has shorted somewhere and is presenting the control system with a temperature the compartment has never seen.

Common Causes of Fault 23

  • Water in the probe connector joining its two pins
  • Insulation worn through where the lead crosses a bracket
  • A probe that has failed to a short internally

🔧 One Safe Check You Can Try

Leave it to a technician, but do mention any recent water spill, hand defrost, or move of the appliance, since a shorted probe circuit usually has a physical cause somebody can point to.

⚠ Why You Shouldn't Go Further Than That

  • Isolate the cabinet at the outlet first - the loom carrying this probe shares its route with mains wiring and the two are not obvious apart.
  • A falsely hot reading makes the control system cool that zone hard, so leaving it running risks freezing whatever is stored there.
  • Drying a wet connector is not a repair unless the path the water took has been found and closed off.
  • These connector shells grip by a plastic latch that goes brittle in the cold, and a latch broken on removal will not hold the plug seated afterwards.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Refrigerator Error Codes

Related Guides

Still Seeing Fault 23?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

FAQ

Fault 23 FAQ

Very likely. A shorted probe reads hot, and a control system told a zone is hot responds by cooling it much harder than it should.

Same probe, opposite failure: 22 is an open circuit reading cold, 23 is a short reading hot, and the wiring check that goes with each is different.