The DG62T27CW1 takes the full-size AeroSmart cabinet and heats it with gas, and the interesting service consequence is that the sensing system now has two quite different things that can make it look wrong. A drifting moisture sensor and a burner that keeps dropping out on flame sensing both present as “the cycle finishes and the clothes are damp”, and only testing separates them.

Key Features

  • AeroSmart gas dryer
  • Auto-sensing drying with dryness levels
  • Gas burner with electronic ignition
  • US and Canada documentation with gas-safety instructions

Most Common Issues on This Model

01

Igniter failure

02

Flame sensing dropping heat mid-cycle

03

Restricted vent causing thermostat short-cycling

04

Moisture sensing drift

Error Codes Common to This Model

Own This Model? Book a Diagnosis.

Have the model number to hand when you book, so the technician arrives knowing which parts this model uses and where it usually fails.

FAQ

Fisher & Paykel DG62T27CW1 FAQ

On a gas AeroSmart it can be either, which is why both the sensing circuit and the burner's flame detection are checked rather than one being assumed.

The gas side is not. The appliance gas valve must be shut off before anyone works near the burner, and that work belongs with a qualified gas technician.